deutsch << www.miniclima.com >> english
- - -
[ Home & News • Product • References • FAQ • Company & Contact • Links ]
|
miniClima Constant Humidity Devices "EBC" - - - Topics EBC Homepage Introduction & Version History Features Build Up In Principle Types & Options Description Air Circulation Filter "FLT" (Optional Accessory) Air Distribution Boxes "LVB" (Optional Accessory) 2.0l Bottle "2LF" (Optional Feature) Detached Operating Unit (Optional Feature) Technical Data Maintenance & Care - - - Description (Current Series EBC10/11) The miniClima Constant Humidity Devices "EBC" serve to keep the relative air-humidity inside a closed case on a constant level without influencing the temperature of the conditioned air. They are used for museum showcases, switchboards, deposit cupboards, containers and similar applications. The essential requirement for efficient operation of the system is that the case should be manufactured both airtight and steamtight. ![]() Left: Hosepipe and parts of the screw connection; Right: Mounted screw connection (Sample images - colours might differ) The case must be connected to the EBC with flexible hoses and screw connectors (all part of the delivery), forming together a tight air circulation system. Also, the miniClima sensor for measuring the temperature and relative humidity must be led inside the case. We use digital sensors and deliver them ready-to-use with housing, cable and RJ45 plug. The same kind of plug is used for the control lines, which are delivered for setting up an EBC chain of one master and one or more slave(s) (common network cables can be used for this purpose as well). ![]() Left: RH/T sensor with cable and plug; Right: Housing and RJ45 plug (Sample images - colours might differ) Once set into operation, the EBC monitors the air condition inside the case and initiates the appropriate action as soon as it becomes necessary: Dehumidification of the system air by condensation of surplus air-humidity or humidification by evaporation of condensate or distillate. This ensures that the actual humidity level will continuously be brought into line with the setpoint. The changes in the humidity level are more gradual the closer the actual RH level approaches to the setpoint. All the while the EBC continually circulates the air between case and EBC independently from the currently required process. The air is always exhausted from the case, led into the device where it will be conditioned if required, or left untreated and then returned back into the case again. The whole process takes place without intermingling system air and outside air. The water (actually: distillate and condensate) that is used for the EBC's work is recirculated from the bottle to the inside of the EBC and back again repeatedly on both a regular basis and following the requirements of the current process. Through this continuous movement biological growth is virtually eliminated and EBC-induced problems with bacteria formation have never been reported to us. Like its predecessor the new series EBC10/11 consists of two models for different air-volumes to be processed, EBC10 (max. 3m3) and EBC11 (max. 5m3). The new units are no longer classified as masters and slaves. The possibility still exists to add more units to one case for increasing the capacity. Now every model from the series has the potential of becoming both a fully functional master unit or a slave unit as required. The decision for one of the two hierarchic states is selected automatically dependant upon the type of cable connected to the EBC. If it is the cable from the miniClima RH/T sensor, then the EBC becomes a master controller. If it is the control line coming from another EBC then the unit becomes a slave and will duplicate the function of the EBC that is the first in the line. This new classification will help the user when he wants to rearrange exhibitions, keep a qualified unit in stock, or when he/she needs to provide for at least some humidity control even if the actual master unit fails. EBC10 in standard configuration The miniClima devices require electric supply through a standard socket-outlet. No water-pipe installation is required, the unit being completely self contained. All condensate or distillate is stored and taken from the unit's own water bottle. The bottle can be positioned to the front of the EBC as well as to the side, so as to fit more easily into restricted areas. The bottle is secured with a belt and (by default) always monitored against overflowing (high level alarm). In addition to this high water level alarm, all devices of series EBC10/11 can be ordered equipped with a low water level alarm (optional extra). And in those cases where the customer requests it, and where it is also possible with respect to safety considerations, an EBC can be delivered without any sensors for the water level in the bottle at all (cost reduction). Other alarms that are issued by the EBC refer to the humidity level being above or below the customer preset levels, the overall water handling system of the EBC (i.e. torn or blocked silicone pipe), and the presence and quality of the signals coming in from the RH/T sensor or the master unit (i.e. broken cable). If an alarm occurs, the green LED on the front panel turns red and the display informs the user of the alarm status. Each device is equipped with two potential-free switch-over contacts for wiring the EBC with external installations - i.e. in a control room. First, a composite error alarm, and second a signal informing the on/off status of the unit. The user can therefore be ensured of being notified immediately when a non-routine intervention is needed. By popular request series EBC10/11 also brings back the built-in audible composite error alarm, which can be activated from the menu (default setting is "off"). An all new miniClima datalogger hardware is now part of the control system built into the EBC and is provided with every unit. The new software ("miniClima EBC Tool") is supplied free of charge with each order, and allows up to 15,000 values to be stored and read out. The user can check for alarms that occurred or settings that have been changed. He can also use them to have "live" access to the currently present values. Each device is delivered ready-to-install complete with all required parts including hoses, hose connectors and cables, as well as (once per order) installation and documentation CDs with the miniClima EBC Tool and detailed user guides. - - - Continue with Air Circulation Filter "FLT" (Optional Accessory) - - - - - - Return to Top of this page Previous page - - - |
![]()
[ General Terms & Conditions • Disclaimer • Imprint ]
- - -
© miniClima Schönbauer GmbH, Höggerlgasse 11, A 2700 Wiener Neustadt. All rights reserved.
Last update/review of this page: 03.07.10